The automatic mask filling machine is a common equipment for modern mask manufacturers. The automatic multi-process integration is completed by a single machine, which also greatly saves the labor cost faced by the enterprise, improves the quality and production efficiency, and improves the standard consistency of the product. The performance of this machine is stable. , high efficiency and accurate filling, it is the first choice for mask manufacturers to turn to automated mass production!
Simple troubleshooting of automatic mask filling machine:
1. No display when power on
Check whether the three-phase four-wire power line connected is correct, whether the neutral wire is connected correctly; whether the air switch inside the equipment is closed; whether the power switch on the operation panel is clocked.
2. The cylinders of bag dropping, bag opening, filling head, filling, exhaust, and sealing do not work; bag dropping vacuum and bag opening vacuum solenoid valves don’t work
Enter the "Indicator" output monitoring screen to check whether the corresponding action has output; check whether the corresponding solenoid valve is connected and whether there is reversing; check whether the corresponding air pipe is blocked, broken or disconnected; check whether the cylinder throttle valve is open or not. Damaged; check whether the cylinder is damaged or the mechanism is stuck.
3. Alarm for bag empty (bag missing)
Enter the "indicator light" input monitoring screen to check whether there is a signal for the bag drop inspection indicator, and check whether the bag detection sensor is adjusted or damaged; check whether there is a shortage of bags on the conveyor belt at the corresponding position of the bag drop machine, and fill up the missing bags. Can.
4. Alarm when bag drop is not in place
Enter the "Indicator Indicator" input monitoring screen to check whether there is a signal from the bag-feeding sensor; check whether the bag-feeding sensor is damaged; check whether there is any problem with the bag-feeding cylinder.
5. Alarm if the bag is returned and not in place
Enter the "Indicator" input monitoring screen to check whether there is a signal from the bag drop return position sensor; check whether the bag drop return position sensor is damaged; check whether there is any problem with the bag drop cylinder action.
6. Alarm when the filling head does not fall in place
Enter the "Indicator Indicator" input monitoring screen to check whether there is a signal from the filling head down position sensor; check whether the filling head down position sensor is damaged; check whether there is any problem with the filling head cylinder movement.
7. Alarm when the filling head does not rise fully
Enter the "Indicator Indicator" input monitoring screen to check whether there is a signal from the filling head up-to-position sensor; check whether the filling head up-to-position sensor is damaged; check whether there is any problem with the filling head cylinder movement.
8. Open bag vacuum alarm
Check whether the corresponding bag on the conveyor belt at the bag opening position is tilted or its position is adjusted. After the manual placement is correct, whether it is tilted or its position is reversed. After the manual placement is correct, press "Open Bag Reset" on the man-machine interface to open the bag again; check Whether the vacuum degree of the vacuum detection meter is set too high; check whether the vacuum meter is damaged or the line is broken; check whether the bag opening vacuum suction cup and the pipeline are blocked or damaged; enter the "indicator light" output monitoring screen to check whether the vacuum valve of the bag drop has an action output; Check the vacuum valve relay or vacuum valve for open or damaged, check the vacuum machine for open or damaged.